  • INGEAR PLC ActiveX, Visual Studio.NET, OPC Server, dashboard instrumentation and graphics tools for Allen-Bradley, MODBUS, GE-FANUC and OMRON programmable logic and automation controllers. CimQuest INGEAR is a leading supplier of runtime-free software development solutions for industrial applications.
  • Siemens S7 TCP Autodetect Wizard. For how to search a network for Siemens S7 PLC Devices and automatically create tags for any PLC Devices found. Siemens S7 Driver. For information on the Siemens S7 Driver. Fernhill SCADA Drivers. For information about other drivers available in Fernhill SCADA. For the meaning of terms used in.

Download the latest drivers, firmware, and software for your HP USB 2.0 2005pr Port Replicator.This is HP’s official website that will help automatically detect and download the correct drivers free of cost for your HP Computing and Printing products for Windows and Mac operating system.

Help Contents

Introduction

Fernhill SCADA supports these types of connection to S7-200 PLC Devices:

  • Direct serial connection,
  • Serial connection using a PPI adapter,
  • Ethernet connection using an Ethernet Module.

Direct Connection

You can connect Fernhill SCADA directly to an S7-200 PLC Device using a standard RS-485 adapter:

Setup Notes:

  • The RS-232 connection from the computer running Fernhill SCADA to the RS-232 to RS-485 Adapter should include the TXD, RXD and RTS signals.
  • The RS-232 to RS-485 adapter must be configured for 2-wire mode, where the transmitter is enabled by an active RTS signal.
  • Use Profibus cable (or equivalent) to connect the S7-200 PLC to the RS-485 Adapter. A standard Profibus connector simplifies the connection to the S7-200 PLC. RS-485 adapters typically have four screw terminal connections often marked RX+, RX-, TX+, TX-. Connect the Profibus Red conductor to the RX+ and TX+ terminals, connect the Profibus Green conductor to the RX- and TX- terminals.
  • Termination resistors should be used at both ends of the Profibus cable.
  • For best reliability, the RS-232 port should be a direct peripheral port on the computer running Fernhill SCADA. Use of USB connected serial ports can introduce inter-character delays, which can result in communication dropouts.
  • Use the Siemens S7 PPI Autodetect Wizard to automatically discover the correct communication parameters and configure Fernhill SCADA.

Manual Configuration of a Direct Connection

To manually configure Fernhill SCADA for direct connection to an S7-200 PLC:

  1. Create a Siemens S7 PPI Channel Tag
  2. The Mode settings of the Siemens S7 PPI Channel Tag should be configured to: Baud=9600 Parity=E Data=8 Stop=1 RTS=Tg. The Baud=9600 option matches the default baud rate of S7-200 PLC Devices. The RTS=Tg option tells the serial port hardware to make the RTS signal active during transmit.
  3. Create a Siemens S7 Serial PLC Tag that references the channel.

Connection Using a PPI Adapter

You can connect Fernhill SCADA to S7-200 PLC Devices using a PPI adapter:

Siemens Port Devices driver

General Setup Notes:

Vga
  • When connecting to a single S7-200 PLC, the PPI - RS485 connection of the PPI Adapter can be connected directly to the S7-200 PLC.
  • When connecting more than one S7-200 PLC, use standard Profibus cable (or equivalent) to connect the PLC Devices together. Fit one Profibus connector with a programming port, and connect the PPI - RS485 connection of the PPI Adapter to that connector.
  • Use the Siemens S7 PPI Autodetect Wizard to automatically discover the correct communication parameters and configure Fernhill SCADA.

Manual Configuration of a Connection using a PPI Adapter

Siemens Port Devices Drivers

To manually configure Fernhill SCADA for connection to S7-200 PLC Devices using a PPI adapter:

  1. Create a Siemens S7 PPI Channel Tag
  2. The Mode settings of the Siemens S7 PPI Channel Tag should match the setup of the adapter. See the tables below for the appropriate Mode settings and adapter switch settings
  3. Create a Siemens S7 Serial PLC Tag that references the channel.
Siemens

Setup Notes for 6ES7 901-3CB30-0XA0:

  • There are 8 switches on the side of the 6ES7 901-3CB30-0XA0 adapter labelled SW1 to SW8. To work with Fernhill SCADA the switch settings need to be setup correctly.
  • SW1, SW2 and SW3 on the PPI Adapter define the communication speed of the RS-232 port. These switches should match the Mode settings of the Siemens S7 PPI Channel Tag. The Mode setting should be set to Baud=nnnn Parity=E Data=8 Stop=1, where nnnn is chosen to match SW1 to SW3:
    BaudSW1SW2SW3
    Baud=115200110
    Baud=57600111
    Baud=38400000
    Baud=19200001
    Baud=9600010

  • SW5 should be set to '0' (Freeport Mode). SW6 should be set to '0' (DCE Mode). SW7 should be set to '0' (11 Bit).

Setup Notes for 6ES7 901-3BF21-0XA0:

Devices
  • There are 6 switches on the side of the 6ES7 901-3BF21-0XA0 adapter labelled SW1 to SW6. To work with Fernhill SCADA these switch settings need to be setup correctly.
  • SW1, SW2 and SW3 on the PPI Adapter define the communication speed of the RS-232 port. These switches should match the Mode settings of the Siemens S7 PPI Channel Tag. The Mode setting should be set to Baud=nnnn Parity=E Data=8 Stop=1, where nnnn is chosen to match SW1 to SW3:
    BaudSW1SW2SW3
    Baud=115200000
    Baud=57600000
    Baud=38400000
    Baud=19200001
    Baud=9600010

  • SW4 should be set to '0' (11 Bit Mode). SW5 should be set to '0' (DCE Mode). SW6 should be set to '0' (RTS on always).

Ethernet Connection using a CP 243-1 Module

You can connect Fernhill SCADA to an S7-200 PLC using an Ethernet module:

Fernhill SCADA supports these S7-200 Ethernet modules:

Sirius USB2.0 Camera - Driver Download. Vendor:. Product: Sirius USB2.0 Camera. Hardware Class: Media. Search For More Drivers.: Go! Windows 10 32-Bit. Download sirius driver.

Siemens Port Devices Driver Vga

  • 6GK7 243-1EX00-0XE0
  • 6GK7 243-1EX01-0XE0
  • 6GK7 243-1GX00-0XE0

For a detailed overview of setting up an S7-200 Ethernet module refer to Siemens S7-200 Ethernet Connection Guide.

If the S7-200 module is configured, you can use the Siemens S7 TCP Autodetect Wizard to try and locate the PLC on the network.

Further Information

For a step by step guide to configuring tags for Siemens S7 PPI connected PLC Devices.

For how to configure an S7-200 Ethernet module and Fernhill SCADA to work together.

For how to search COM ports for Siemens S7 PLC Devices and automatically create tags for any PLC Devices found.

For how to search a network for Siemens S7 PLC Devices and automatically create tags for any PLC Devices found.

For information on the Siemens S7 Driver.

For information about other drivers available in Fernhill SCADA.

Siemens Port Devices Driver Device

For the meaning of terms used in Fernhill SCADA.

Fernhill SCADA Version 3.66. Copyright © 2012-2021 Fernhill Software Ltd: All rights reserved.

Siemens Port Devices Driver Updater